Pad-mounted Secondary Substation - American Type

Pad-mounted Secondary Substation - American Type

Model No.︰ZGS-12/0.4

Brand Name︰Ayump

Country of Origin︰China

Unit Price︰-

Minimum Order︰1 pc

Inquire Now

Product Description

Pad-mounted Secondary Substation - American Type

.Overview

For American type pad-mounted secondary substation, the transformer iron, winding, medium voltage load switch and fuse switch are all enclosed in one compartment. The advantage for this type of substation is very compact, simplified structure, easy assembling, flexible operation, which can be applied indoor or outdoor.

We have three types: ZGS13-400KVA; ZGS13-500KVA;ZGS13-630KVA

.Environmental conditions

1. elevation: over 1,000 m above;

2. Ambient temperature: higher than + 40℃ and lower than-25℃; upper average daily temperature difference exceeds 35℃; annual average temperature difference exceeds 20℃;

3. More than 35m/s in the wind speed;

4. The installation site has no explosion danger, no chemical corrosion and violent vibration;

5. Cooling mode: Air self-cooling (AN).

.Specification

Item

Unit

Specification

Rated voltage

Kv

10/0.4(HV/LV)

Rated Capacity

kVA

100~1250

Maximum operating voltage

Kv

12(HV side)

Rated frequency

Hz

50

Rated capacity

Kva

50-1600

1min Power-frequency withstand voltage

Kv

35

Lightning impulse withstand voltage

Kv

75

Cooling-down method

 

ONAN

High voltage backup fuse open current

Ka

50

Plug-in fuse open current

Ka

2.5

Ambient temperature

-35~+45

The coil allows for a temperature rise

65

No-load pressure adjustment

 

±5%(or)±2×2.5%

Noise grade

Db

50

IP Rating

 

IP43

.Features

1.Low noise, low loss, high reliability.

2.Small volume and compact structure to facilitate assembling.

3.Completely screened and insulated structure, double fuses protection, the fuses are dual-sensitive fuses(temperature-sensitive, current-sensitive).

4.Suitable for ring main and terminal power distribution networks.

5. Cable connector structure is used for incoming line, which gives the characteristics of disconnecting switch, it is easy and flexible in operation.

6.The three-phase three-column structure is employed for transformers, and the step-type seams (Step-lap) process is used for the core, so the transformer has low noise and low loss, good anti-short-circuit and overload abilities.

7.High fire point insulating oil is employed, the surface of the transformer is treated to have the abilities of fungus resistance, moisture resistance and salt spray resistance.